- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Pilot/Drain | Internal Pilot/External Drain |
| Spool Code | 2 |
| Crossover | All Ports Blocked |
| Performance | Standard Performance |
| Actuator Type | Solenoid |
| Pressure Port Check Valve Pressure | 5 psi |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Body Material | Ductile Iron |
| Electrical Options Code | None |
| Reducer Module | No |
| Actuation Identification | Solenoid A, Solenoid B |
| Solenoid Indicator Lights Code | None |
| Center Position | All Ports Blocked |
| Pilot Valve Type Code | S |
| EN Code | None |
| Gauge Port | SAE-4 |
| Solenoid | Double |
| Spool Indicator Switch Code | None |
| AC/DC | AC |
| Surge Suppressor/Damper | None |
| Temperature Range [Max] | 230 °F |
| Pressure [Max] | 5000 psi |
| Response Type | Standard Response |
| NFPA Size | D08 |
| Spool Spring Arrangement Code | C |
| Compatible Fluids | Petroleum Oil |
| Fluid Cleanliness | 19/17/14 micron |
| Manual Override | Plain Override |
| Spool Control Modification Code | None |
| Coil Rating Code | B |
| Pressure Port Check Valve Code | K |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Electrical Connector Code | None |
| Indicator Lights | No |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Function | 3-Position Spring Centered |
| Design No. | 10 |
| Port Restrictor Plug Code | None |
| Electrical Options | None |
| Coil Type Code | F |
| Seal Material | Buna-N |
| Mechanical Options | None |
| Leakage | Standard Performance |
| Tank Port Rating | 5000 |
| Overrides | Plain Override Solenoid Ends |
| Pilot Pressure Code | None |
| Model No. | DG5V-8-S-2C-K-M-FW-B-10 |
| Response Type Code | None |
| Electrical Connection | No Connector |
| Rated Flow [Max] | 175 gal/min |
| Operation | Pilot Operated |
| Gauge Ports Code | None |
| Reducer Module Code | None |
| Port T Pressure Rating | 5000 psi |
| Temperature Range [Min] | -40 °F |
| Port Restrictor Plugs | None |
| Manual Override Option Code | None |
| Pilot Drain Code | None |
| No. of Stages | Two Stage |
| Valve Type | Standard-Duty |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Mechanical Options Code | None |
| Solenoid Energization Code | None |
| Housing Code | W |
| Mounting | Subplate/Manifold Mount |
| Surge Suppressor/Damper Code | None |
| Weight | 35.0 LB |