Vickers by Danfoss02-324175

02-324175

Vickers D10 Solenoid Valve
Item #101978192
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-324175
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Compatible Fluids Petroleum Oil
Electrical Connector Code None
Solenoid Energization Code None
Function 3-Position Spring Centered
Operation Pilot Operated
Surge Suppressor/Damper None
Fluid Cleanliness 19/17/14 micron
No. of Stages Two Stage
Pilot Valve Type CETOP 3, Standard Performance
Leakage Standard Performance
Pilot Pressure Code E
Center Position All Ports Blocked
Performance Standard Performance
Design No. 10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure [Max] 5000 psi
Gauge Ports Code None
Reducer Module Code None
Gauge Port SAE-4
Rated Flow [Max] 175 gal/min
AC/DC AC
Spool Spring Arrangement Code C
Actuator Type Solenoid
Body Material Ductile Iron
Tank Port Rating 3000
EN Code None
Port T Pressure Rating 3000 psi
Valve Type Standard-Duty
Electrical Options None
Port Restrictor Plugs None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Electrical Options Code None
Housing Code W
Pilot Drain Code None
Pilot Pressure [Max] 3000 psi
Electrical Connection No Connector
Crossover All Ports Blocked
Response Type Standard Response
Pilot Valve Type Code S
Overrides Plain Override Solenoid Ends
Indicator Lights No
Model No. DG5V-10-S-2C-E-M-FW-B-10
Port Restrictor Plug Code None
Pressure Port Check Valve Pressure N/A
Actuation Identification Solenoid A, Solenoid B
Surge Suppressor/Damper Code None
Spool Control Modification Code None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Mechanical Options None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Seal Material Buna-N
Coil Type Code F
NFPA Size D10
Temperature Range [Min] -0.4 °F
Manual Override Option Code None
Spool Code 2
Response Type Code None
Mounting Subplate/Manifold Mount
Pressure Port Check Valve Code None
Solenoid Double
Temperature Range [Max] 150.8 °F
Solenoid Indicator Lights Code None
Coil Rating Code B
Assembly Code None
Pilot/Drain External Pilot/Internal Drain
Manual Override Plain Override
Reducer Module No
Weight 100.0 LB