Vickers by Danfoss02-321981

02-321981

Vickers D10 Solenoid Valve
Item #102085529
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-321981
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Overrides None
Solenoid Double
Temperature Range [Min] -0.4 °F
Mounting Subplate/Manifold Mount
Pilot Valve Type Code W
Fluid Cleanliness 19/17/14 micron
Spool Spring Arrangement Code C
Assembly Code None
Housing Code W
Compatible Fluids Petroleum Oil
Pressure Port Check Valve Pressure N/A
Temperature Range [Max] 150.8 °F
Surge Suppressor/Damper None
Model No. DG5V-10-W-6C-M-W-B-10
Electrical Options Code None
Body Material Ductile Iron
EN Code None
Pilot Drain Code None
Pressure Port Check Valve Code None
No. of Stages Two Stage
Electrical Connector Code None
Port Restrictor Plug Code None
Tank Port Rating 3000
Operation Solenoid Operated
Coil Type No Coil
Indicator Lights No
Port T Pressure Rating 3000 psi
Actuation Identification Solenoid A, Solenoid B
Pilot Pressure Code None
Response Type Code None
Port Restrictor Plugs None
Manual Override Plain Override
Mechanical Options None
Pilot/Drain External Drain
Center Position P Blocked, A & B to T
Pilot Pressure [Max] 3000 psi
Crossover P Blocked, A or B to T
Manual Override Option Code None
Gauge Ports Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Surge Suppressor/Damper Code None
Function 3-Position Spring Centered
Electrical Connection No Connector
NFPA Size D10
Response Type Standard Response
Design No. 10
Reducer Module N/A
Leakage Standard Performance
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Seal Material Buna-N
AC/DC AC
Pressure [Max] 5000 psi
Solenoid Energization Code None
Electrical Options None
Coil Rating Code B
Spool Control Modification Code None
Rated Flow [Max] 175 gal/min
Valve Type Standard-Duty
Reducer Module Code None
Pilot Valve Type CETOP 5, Wet Armature
Gauge Port SAE-4
Spool Code 6
Coil Type Code None
Weight 100.0 LB