Vickers by Danfoss02-305364

02-305364

Vickers D08 Solenoid Valve
Item #102089001
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-305364
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Aluminum housings can be used for pressures up to 3,000 psi
  • Steel housings must be used for operating pressures above 3,000 psi
Reducer Module N/A
Response Type Standard Response
Voltage & Frequency 110/120 VAC - 50/60 Hz
Solenoid Single
Pilot Drain Code T
Solenoid Energization Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure Port Check Valve Pressure N/A
Pressure [Max] 5000 psi
Model No. DG5V-8-S-0A-E-T-M-FW-B-10
AC/DC AC
Pressure Port Check Valve Code None
EN Code None
Mechanical Options Code None
Port T Pressure Rating 5000 psi
Crossover All Ports Open
Spool Indicator Switch Code None
Coil Type Code F
Electrical Options None
Gauge Ports Code None
Mechanical Options None
Coil Rating Code B
Pilot Pressure Code E
Surge Suppressor/Damper Code None
Design No. 10
Electrical Connector Code None
Spool Code 0
Function 2-Position Spring Offset
Center Position All Ports Open
Pilot Valve Type Code S
Overrides Plain Override Solenoid Ends
Operation Pilot Operated
Tank Port Rating 5000
Surge Suppressor/Damper None
Gauge Port SAE-4
NFPA Size D08
Seal Material Buna-N
Spool Control Modification Code None
Port Restrictor Plug Code None
Solenoid Indicator Lights Code None
Valve Type Standard-Duty
Pilot/Drain External Pilot/Internal Drain
Pilot Valve Type CETOP 3, Standard Performance
Manual Override Plain Override
Manual Override Option Code None
Port Restrictor Plugs None
Indicator Lights No
Rated Flow [Max] 185 gal/min
Electrical Connection No Connector
Spool Spring Arrangement Code A
Response Type Code None
Actuator Type Solenoid
Electrical Options Code None
Housing Code W
Reducer Module Code None
Weight 35.0 LB