Vickers by Danfoss02-300944

02-300944

Vickers D05 Solenoid Valve
Item #102127287
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-300944
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Series 02 two-stage directional valves are designed to meet the requirements of high performance, precision industrial hydraulic systems operating at pressure to 210 bar (3,000 psi) and flows to 130 l/min (34 U.S. gpm), depending on spool type.

features

  • Tapered main spool lands which permit faster operation with less hydraulic shock
  • Advanced design pilot valves provide reduced power consumption without any sacrifice of valve performance
  • Quiet, long-life solenoids can be quickly replaced without disturbing the hydraulic circuitry for easy maintenance
Surge Suppressor/Damper None
Solenoid Double
NFPA Size D05
Spool Spring Arrangement Code C
Overrides Plain Override Solenoid Ends
Coil Type 1/2 in NPT Thread Wiring Housing
Coil Type Code F
Body Material Gray Iron
Reducer Module N/A
Pressure Port Check Valve Code None
Response Type Standard Response
Port T Pressure Rating 1450 psi
AC/DC AC
Actuation Identification Solenoid A, Solenoid B
Pilot Pressure [Min] 75 psi
Solenoid Indicator Lights Code L
Indicator Lights Yes
Temperature Range [Max] 150.8 °F
Seal Material Viton
Electrical Connector Code T
Port Restrictor Plugs None
Spool Indicator Switch Code None
Port Restrictor Plug Code None
Pilot Valve Tank Pressure Rating Code 5
Electrical Options Code None
Pilot/Drain Internal Drain
Pressure [Max] 3000 psi
Center Position All Ports Blocked
Leakage Standard Performance
Pilot Pressure [Max] 3000 psi
Housing Code W
Actuator Type Solenoid
Mounting Subplate/Manifold Mount
Rated Flow [Max] 30 gal/min
Fluid Cleanliness 19/17/14 micron
Electrical Connection Wired Terminal Block
EN Code None
Crossover All Ports Blocked
Solenoid Energization Code None
Electrical Options None
Function 3-Position Spring Centered
Coil Rating Code B
Pilot Valve Type N/A
Pilot Drain Code T
Mechanical Options None
Design No. 20
No. of Stages Two Stage
Model No. F3-DG5S4-02-2C-T-M-FTWL-B5-20
Pilot Pressure Code None
Temperature Range [Min] -0.4 °F
Response Type Code None
Manual Override Plain Override
Compatible Fluids Phosphate Ester Fluids
Valve Type Standard-Duty
Pressure Port Check Valve Pressure N/A
Voltage & Frequency 110/120 VAC - 50/60 Hz
Tank Port Rating 1450
Operation Solenoid Operated
Assembly Code None
Spool Code 2
Spool Control Modification Code None
Manual Override Option Code None
Mounting Screw Option Code None
Weight 13.0 LB