Vickers D03 Solenoid Valve

02-148811

Vickers D03 Solenoid Valve
Item #101854636
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

compliances

  • 0
Performance High Performance
Pressure Port Check Valve Pressure N/A
Mechanical Options None
Model No. DG4V-3-8C-VM-FW-H7-61
Surge Suppressor/Damper None
Solenoid Indicator Lights Code None
Seal Material Buna-N
Mounting Subplate/Manifold Mount
Body Material Gray Iron
Crossover All Ports Open, Restricted
Port T Code 7
Tank Port Rating 3046
Response Time 28 to 45 ms
Spool Spring Arrangement Code C
Spool Shift Timing N/A
Actuation Identification Solenoid A, Solenoid B
Operation Solenoid Operated
Fluid Cleanliness 19/17/14 micron
Rated Flow [Max] 20 gal/min
Manual Override Plain Override
No. of Stages Single Stage
Pilot/Drain None
Temperature Range [Max] 158 °F
Reducer Module No
Design No. 61
Port Restrictor Plugs None
Valve Type High-Performance
Manual Override Option Code None
Spool Indicator Switch Code None
Indicator Lights No
Spool Code 8
Electrical Connector Code None
Solenoid Energization Code V
Coil Rating Code H
Function 3-Position, 4-Way, Spring Centered
Coil Type Code F
Overrides No Overrides
Manufacturer Part No. DG4V 3 8C V M FW H7 61
Leakage Standard Performance
Compatible Fluids Petroleum Oil
AC/DC DC
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connection Terminal Box
Center Position P to T, A & B Blocked
Electrical Options None
Port Restrictor Plug Code None
Actuator Type Solenoid
Housing Code W
NFPA Size D03
Voltage & Frequency 24 VDC
Cycle Rate [Max] N/A
Temperature Range [Min] -4 °F
Surge Suppressor/Damper Code None
Pilot Valve Type N/A
Watt Rating 30 W
Solenoid Double
Response Type Standard Response
Solenoid Code H
Rated Flow 10.6 gal/min
EN Code None
Port T Pressure Rating 3000 psi
Function Code 8
Pressure [Max] 5000 psi
Weight 4.6 LB