Vickers D03 Solenoid Valve

02-147442

Vickers D03 Solenoid Valve
Item #102038731
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Spool Code 2
Spool Indicator Switch Code None
Electrical Connector Code PA5
Spool Center Condition A Port and Double Offset sensing switch on B Port
Leakage Standard Performance
NFPA Size D03
Model No. DG4V-3-2C-M-FPA5WL-H7-60
No. of Stages Single Stage
Mounting Subplate/Manifold Mount
Port Restrictor Plugs None
Manual Override Plain Override
Manual Override Option Code None
Pilot Valve Type N/A
Function 3-Position Spring Centered
Temperature Range [Max] 158 °F
Operation Solenoid Operated
Solenoid Double
Electrical Options None
Performance Standard Performance
Body Material Gray Iron
Design No. 60
Valve Type High-Performance
AC/DC DC
Voltage & Frequency 24 VDC
Response Time 28 to 45 ms
Port T Pressure Rating 3000 psi
Tank Port Rating 3046
Cycle Rate [Max] N/A
Watt Rating 30 W
Compatible Fluids Petroleum Oil
Port T Code 7
Actuator Type Solenoid
EN Code None
Temperature Range [Min] -4 °F
Pressure Port Check Valve Pressure N/A
Center Position All Ports Blocked
Electrical Connection Five Pin Connector
Pressure [Max] 5000 psi
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Crossover All Ports Blocked
Spool Shift Timing N/A
Solenoid Energization Code None
Actuation Identification Solenoid A, Solenoid B
Coil Rating Code H
Surge Suppressor/Damper None
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plug Code None
Rated Flow [Max] 20 gal/min
Overrides No Overrides
Surge Suppressor/Damper Code None
Spool Spring Arrangement Code C
Solenoid Code H
Housing Code W
Mechanical Options None
Function Code 2
Pilot/Drain None
Reducer Module No
Indicator Lights Yes
Seal Material Buna-N
Response Type Standard Response
Solenoid Indicator Lights Code L
Coil Type Code F
Weight 5.0 LB