Vickers D03 Solenoid Valve

02-147420

Vickers D03 Solenoid Valve
Item #101854633
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Tank Port Rating 3046
Model No. DG4V 3 0C M FTWL B6 60
Solenoid Double
Seal Material Buna-N
Pressure Port Check Valve Pressure N/A
Port T Pressure Rating 3000 psi
Fluid Cleanliness 19/17/14 micron
Manual Override Plain Override
Body Material Gray Iron
Function 3-Position, 4-Way, Spring Centered
Surge Suppressor/Damper None
NFPA Size D03
Leakage Standard Performance
Electrical Connection Wired Terminal Block
Electrical Connector Code T
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Indicator Lights Yes
Pilot Valve Type N/A
Temperature Range [Max] 158 °F
Mechanical Options None
Rated Flow 21.00 gal/min
Overrides No Overrides
Electrical Options None
Port Restrictor Plugs None
Rated Flow [Max] 20.00 gal/min
Center Position All Ports Open
Spool Shift Timing N/A
Mounting Manifold Mount
Cycle Rate [Max] 0
Compatible Fluids Petroleum Oil
No. of Stages Single Stage
Coil Type Code F
Voltage & Frequency 110/120 VAC - 50/60 Hz
Manual Override Option Code None
Actuation Identification Solenoid A, Solenoid B
Function Code 0
Temperature Range [Min] -4 °F
Crossover All Ports Open
AC/DC AC
Actuator Type Solenoid
Response Type Standard Response
Manufacturer Part No. DG4V 3 0C M FTWL B6 60
Pressure [Max] 5,075 psi
Spool Code 0
Reducer Module No
Spool Indicator Switch Code None
Port Restrictor Plug Code None
Spool Spring Arrangement Code C
Design No. 60
Port T Code 6
Solenoid Energization Code None
Solenoid Indicator Lights Code L
Coil Rating Code B
Performance High Performance
Solenoid Code B
Operation Solenoid Operated
Response Time 15 to 23 ms
Valve Type High-Performance
Surge Suppressor/Damper Code None
Pilot/Drain None
EN Code None
Housing Code W
Weight 4.6 LB