Vickers D03 Solenoid Valve

02-147420

Vickers D03 Solenoid Valve
Item #101854633
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Temperature Range [Min] -4 °F
Electrical Connector Code T
Port T Code 6
Electrical Connection Wired Terminal Block
Indicator Lights Yes
AC/DC AC
Manual Override Plain Override
Design No. 60
Function Code 0
Manual Override Option Code None
Fluid Cleanliness 19/17/14 micron
Cycle Rate [Max] 0
Pilot/Drain None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Surge Suppressor/Damper None
Pressure Port Check Valve Pressure N/A
Port T Pressure Rating 3000 psi
Mounting Manifold Mount
Rated Flow [Max] 20.00 gal/min
Rated Flow 21.00 gal/min
Spool Code 0
Solenoid Energization Code None
Electrical Options None
Pilot Valve Type N/A
Compatible Fluids Petroleum Oil
Solenoid Double
Function 3-Position, 4-Way, Spring Centered
Response Time 15 to 23 ms
Body Material Gray Iron
Overrides No Overrides
Center Position All Ports Open
Actuation Identification Solenoid A, Solenoid B
Model No. DG4V 3 0C M FTWL B6 60
Spool Indicator Switch Code None
Crossover All Ports Open
Seal Material Buna-N
Solenoid Code B
Coil Type Code F
Spool Spring Arrangement Code C
Temperature Range [Max] 158 °F
Housing Code W
Port Restrictor Plugs None
Spool Shift Timing N/A
Leakage Standard Performance
Tank Port Rating 3046
Coil Rating Code B
Port Restrictor Plug Code None
Operation Solenoid Operated
Pressure [Max] 5,075 psi
Performance High Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Reducer Module No
No. of Stages Single Stage
EN Code None
NFPA Size D03
Response Type Standard Response
Manufacturer Part No. DG4V 3 0C M FTWL B6 60
Solenoid Indicator Lights Code L
Valve Type High-Performance
Mechanical Options None
Surge Suppressor/Damper Code None
Actuator Type Solenoid
Weight 4.6 LB