Vickers D03 Solenoid Valve

02-144984

Vickers D03 Solenoid Valve
Item #101855888
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Tank Port Rating 3046
Spool Code 8
Function Code 8
Manufacturer Part No. DG4V 3 8C V M FTWL B6 61
Solenoid Energization Code V
Surge Suppressor/Damper None
Seal Material Buna-N
Rated Flow 21.00 gal/min
Pilot Valve Type N/A
Port Restrictor Plug Code None
Cycle Rate [Max] 0
Port T Pressure Rating 3000 psi
Performance Standard Performance
Compatible Fluids Petroleum Oil
Leakage Standard Performance
Reducer Module No
Spool Spring Arrangement Code C
Valve Type High-Performance
Temperature Range [Max] 158 °F
Mechanical Options None
Electrical Options None
Watt Rating 20 W
Body Material Gray Iron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Center Condition A Port and Double Offset sensing switch on B Port
Manual Override Plain Override
Rated Flow [Max] 20.00 gal/min
Coil Rating Code B
Overrides No Overrides
Temperature Range [Min] -4 °F
Surge Suppressor/Damper Code None
Mounting Manifold Mount
Electrical Connection Wired Terminal Block
Operation Solenoid Operated
Port T Code 6
Housing Code W
Pilot/Drain None
Actuator Type Solenoid
AC/DC AC
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plugs None
Actuation Identification Solenoid A, Solenoid B
Manual Override Option Code None
Spool Shift Timing N/A
Indicator Lights Yes
Solenoid Code B
Coil Type Code F
Spool Indicator Switch Code None
NFPA Size D03
Electrical Connector Code T
Pressure Port Check Valve Pressure N/A
Solenoid Indicator Lights Code L
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Function 3-Position, 4-Way, Spring Centered
No. of Stages Single Stage
Crossover All Ports Open, Restricted
Response Type Standard Response
Pressure [Max] 5,075 psi
Solenoid Double
Response Time 15 to 23 ms
Model No. DG4V-3-8C-VM-FTWL-B6-61
Design No. 61
Center Position P to T, A & B Blocked
EN Code None
Weight 5.0 LB