Vickers D03 Solenoid Valve

02-144984

Vickers D03 Solenoid Valve
Item #101855888
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Leakage Standard Performance
Cycle Rate [Max] 0
Solenoid Indicator Lights Code L
Function Code 8
Port T Code 6
EN Code None
Temperature Range [Max] 158 °F
Compatible Fluids Petroleum Oil
Port T Pressure Rating 3000 psi
Spool Code 8
Watt Rating 20 W
Actuator Type Solenoid
Rated Flow [Max] 20.00 gal/min
Solenoid Energization Code V
Surge Suppressor/Damper Code None
Center Position P to T, A & B Blocked
Electrical Connection Wired Terminal Block
Manufacturer Part No. DG4V 3 8C V M FTWL B6 61
Mounting Manifold Mount
Coil Type Code F
Electrical Options None
Pilot Valve Type N/A
Temperature Range [Min] -4 °F
Solenoid Double
Spool Shift Timing N/A
Indicator Lights Yes
Spool Center Condition A Port and Double Offset sensing switch on B Port
Overrides No Overrides
No. of Stages Single Stage
Pressure [Max] 5,075 psi
NFPA Size D03
Solenoid Code B
Performance Standard Performance
Tank Port Rating 3046
Response Time 15 to 23 ms
Body Material Gray Iron
Crossover All Ports Open, Restricted
Port Restrictor Plug Code None
Valve Type High-Performance
Operation Solenoid Operated
Housing Code W
Model No. DG4V-3-8C-VM-FTWL-B6-61
Surge Suppressor/Damper None
Electrical Connector Code T
Spool Spring Arrangement Code C
Seal Material Buna-N
Manual Override Plain Override
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Indicator Switch Code None
Manual Override Option Code None
Response Type Standard Response
Voltage & Frequency 110/120 VAC - 50/60 Hz
Reducer Module No
Function 3-Position, 4-Way, Spring Centered
Pressure Port Check Valve Pressure N/A
Design No. 61
AC/DC AC
Fluid Cleanliness 19/17/14 micron
Actuation Identification Solenoid A, Solenoid B
Pilot/Drain None
Mechanical Options None
Rated Flow 21.00 gal/min
Coil Rating Code B
Port Restrictor Plugs None
Weight 5.0 LB