Vickers D03 Solenoid Valve

02-144984

Vickers D03 Solenoid Valve
Item #101855888
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Valve Type High-Performance
Spool Indicator Switch Code None
AC/DC AC
Center Position P to T, A & B Blocked
Surge Suppressor/Damper None
Indicator Lights Yes
Mechanical Options None
Port T Pressure Rating 3000 psi
Design No. 61
Spool Shift Timing N/A
Electrical Connection Wired Terminal Block
Solenoid Code B
Electrical Connector Code T
Tank Port Rating 3046
Manual Override Plain Override
Seal Material Buna-N
Temperature Range [Min] -4 °F
Body Material Gray Iron
Function 3-Position, 4-Way, Spring Centered
Port T Code 6
NFPA Size D03
Coil Type Code F
Solenoid Energization Code V
Pilot/Drain None
Spool Code 8
Manufacturer Part No. DG4V 3 8C V M FTWL B6 61
Solenoid Double
Temperature Range [Max] 158 °F
Crossover All Ports Open, Restricted
Fluid Cleanliness 19/17/14 micron
EN Code None
Housing Code W
Spool Spring Arrangement Code C
Pressure Port Check Valve Pressure N/A
Actuator Type Solenoid
Electrical Options None
Response Time 15 to 23 ms
Model No. DG4V-3-8C-VM-FTWL-B6-61
Watt Rating 20 W
Compatible Fluids Petroleum Oil
Port Restrictor Plug Code None
Overrides No Overrides
Operation Solenoid Operated
Port Restrictor Plugs None
No. of Stages Single Stage
Surge Suppressor/Damper Code None
Rated Flow [Max] 20.00 gal/min
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Rating Code B
Function Code 8
Pilot Valve Type N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Center Condition A Port and Double Offset sensing switch on B Port
Manual Override Option Code None
Cycle Rate [Max] 0
Reducer Module No
Solenoid Indicator Lights Code L
Response Type Standard Response
Mounting Manifold Mount
Pressure [Max] 5,075 psi
Rated Flow 21.00 gal/min
Performance Standard Performance
Actuation Identification Solenoid A, Solenoid B
Leakage Standard Performance
Weight 5.0 LB