Skip to content Skip to navigation menu
Vickers by Danfoss02-141552

02-141552

Vickers D07 Solenoid Valve
Item #101908189
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-141552
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Housing Code None
Surge Suppressor/Damper None
Leakage Standard Performance
Tank Port Rating 1450
Solenoid Single
Assembly Code None
Electrical Connector Code None
Operation Solenoid Operated
Electrical Options None
Response Type Standard Response
Coil Type Code U
EN Code None
Actuator Type Solenoid
Crossover P Blocked, A or B to T
No. of Stages Two Stage
Electrical Connection No Connector
Spool Code 6
Reducer Module N/A
Spool Indicator Switch Code None
Port Restrictor Plugs None
Compatible Fluids Petroleum Oil
Mechanical Options None
Pilot/Drain Internal Drain
Function 2-Position Spring Offset
Pressure [Max] 3000 psi
Valve Type Standard-Duty
Coil Type ISO 4400
Port Restrictor Plug Code None
Coil Rating Code B
Pressure Port Check Valve Code None
Performance Standard Performance
Spool Spring Arrangement Code A
AC/DC AC
Indicator Lights No
Center Position P Blocked, A & B to T
Design No. 60
Electrical Options Code None
Model No. DG5S4-046A-T-M-U-B5-60
Rated Flow [Max] 60 gal/min
Response Type Code None
Mounting Screw Option Code N/A
Fluid Cleanliness 19/17/14 micron
Mounting Subplate/Manifold Mount
Manual Override Plain Override
Pressure Port Check Valve Pressure N/A
Spool Control Modification Code None
Solenoid Energization Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Manual Override Option Code None
Pilot Valve Tank Pressure Rating Code 5
Solenoid Indicator Lights Code None
Pilot Valve Type N/A
Pilot Drain Code T
Body Material Gray Iron
Actuation Identification Solenoid B
Port T Pressure Rating 1450 psi
Overrides Plain Override Solenoid Ends
NFPA Size D07
Seal Material Buna-N
Pilot Pressure Code None
Weight 15.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle