Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-139078

Vickers D03 Solenoid Valve
Item #102000387
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Up to 21 gpm at 5,000 psi
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
Pressure Port Check Valve Pressure N/A
Temperature Range [Min] -4 °F
Valve Type High-Performance
Port Restrictor Plug Code None
Port T Code 7
Solenoid Code HL
Spool Code 2
Solenoid Energization Code None
Manual Override Plain Override
Manual Override Option Code None
Rated Flow [Max] 20 gal/min
Compatible Fluids Petroleum Oil
Fluid Cleanliness 19/17/14 micron
Reducer Module No
Mechanical Options None
Watt Rating 18 W
Operation Solenoid Operated
Seal Material Buna-N
Indicator Lights Yes
Housing Code W
Spool Spring Arrangement Code A
Cycle Rate [Max] N/A
Pilot/Drain None
NFPA Size D03
Overrides No Overrides
No. of Stages Single Stage
Mounting Subplate/Manifold Mount
Surge Suppressor/Damper None
Performance High Performance
Electrical Connection Wired Terminal Block
Tank Port Rating 3046
Model No. DG4V 3 2A M FTWL HL7 60
Response Type Standard Response
Crossover All Ports Blocked
Pressure [Max] 5000 psi
Solenoid Single
Temperature Range [Max] 158 °F
Actuator Type Solenoid
Function 2-Position Spring Offset, End to End
Port Restrictor Plugs None
Voltage & Frequency 24 VDC
Surge Suppressor/Damper Code None
Port T Pressure Rating 3000 psi
Electrical Options None
Actuation Identification Solenoid B
Coil Type Code F
EN Code None
Center Position All Ports Blocked
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Body Material Gray Iron
Leakage Standard Performance
Coil Rating Code HL
Spool Indicator Switch Code None
Electrical Connector Code T
Design No. 60
Function Code 2
Response Time 28 to 45 ms
Pilot Valve Type N/A
AC/DC DC
Spool Shift Timing N/A
Solenoid Indicator Lights Code L
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison