Vickers D03 Solenoid Valve

02-139001

Vickers D03 Solenoid Valve
Item #102036788
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Crossover P Blocked, A or B to T
Coil Type ISO 4400
Port T Pressure Rating 3000 psi
Leakage Standard Performance
Fluid Cleanliness 19/17/14 micron
Indicator Lights No
Mounting Subplate/Manifold Mount
Rated Flow [Max] 20 gal/min
No. of Stages Single Stage
Pressure Port Check Valve Pressure N/A
Solenoid Indicator Lights Code None
Port Restrictor Plug Code None
Electrical Options None
AC/DC DC
Electrical Connection DIN 43650
Seal Material Buna-N
Surge Suppressor/Damper None
Center Position P Blocked, A & B to T
Overrides No Overrides
Coil Rating Code HL
Pressure [Max] 5000 psi
Solenoid Code HL
Port T Code 7
Valve Type High-Performance
Response Type Standard Response
Performance High Performance
Cycle Rate [Max] N/A
Manual Override Plain Override
Reducer Module No
EN Code None
NFPA Size D03
Spool Indicator Switch Code None
Temperature Range [Min] -4 °F
Compatible Fluids Petroleum Oil
Voltage & Frequency 24 VDC
Body Material Gray Iron
Spool Code 6
Tank Port Rating 3046
Solenoid Single
Electrical Connector Code None
Model No. DG4V 3 6A M U HL7 60
Operation Solenoid Operated
Temperature Range [Max] 158 °F
Spool Spring Arrangement Code A
Function 2-Position Spring Offset, End to End
Solenoid Energization Code None
Pilot Valve Type N/A
Port Restrictor Plugs None
Coil Type Code U
Response Time 28 to 45 ms
Manual Override Option Code None
Actuation Identification Solenoid B
Spool Shift Timing N/A
Watt Rating 18 W
Function Code 6
Housing Code None
Actuator Type Solenoid
Mechanical Options None
Design No. 60
Surge Suppressor/Damper Code None
Pilot/Drain None
Weight 5.0 LB