Vickers D03 Solenoid Valve

02-137912

Vickers D03 Solenoid Valve
Item #101983291
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Pilot/Drain None
Port Restrictor Plug Code None
Spool Spring Arrangement Code N
AC/DC DC
Indicator Lights No
Watt Rating 18 W
Manual Override Option Code None
NFPA Size D03
Leakage Standard Performance
Crossover All Ports Blocked
Solenoid Indicator Lights Code None
No. of Stages Single Stage
Spool Center Condition A Port and Double Offset sensing switch on B Port
Electrical Options None
Actuator Type Solenoid
Tank Port Rating 3046
Overrides No Overrides
Mounting Subplate/Manifold Mount
Center Position All Ports Blocked
Voltage & Frequency 24 VDC
Solenoid Double
Spool Shift Timing N/A
Coil Type Code U
Port T Code 7
Rated Flow [Max] 20 gal/min
Port T Pressure Rating 3000 psi
Port Restrictor Plugs None
Solenoid Code HL
Solenoid Energization Code None
Coil Type ISO 4400 (Din 43650) Connector
Pressure Port Check Valve Pressure N/A
Electrical Connector Code None
Manual Override Plain Override
Fluid Cleanliness 19/17/14 micron
Temperature Range [Min] -4 °F
Function Code 2
Response Type Standard Response
Electrical Connection DIN 43650
Spool Indicator Switch Code None
Mechanical Options None
Coil Rating Code HL
Performance Standard Performance
Model No. DG4V 3 2N M U HL7 60
Surge Suppressor/Damper Code None
Pilot Valve Type N/A
Compatible Fluids Petroleum Oil
Response Time 28 to 45 ms
Reducer Module No
Design No. 60
Valve Type High-Performance
Cycle Rate [Max] N/A
Body Material Gray Iron
EN Code None
Actuation Identification Solenoid A, Solenoid B
Pressure [Max] 5000 psi
Housing Code None
Operation Solenoid Operated
Function 3-Position Detented
Seal Material Buna-N
Temperature Range [Max] 158 °F
Surge Suppressor/Damper None
Spool Code 2
Weight 5.0 LB