Vickers D05 Solenoid Valve
Item #102022289
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-134930
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • Series 02 two-stage directional valves are designed to meet the requirements of high performance, precision industrial hydraulic systems operating at pressure to 210 bar (3,000 psi) and flows to 130 l/min (34 U.S. gpm), depending on spool type.

features

  • Tapered main spool lands which permit faster operation with less hydraulic shock
  • Advanced design pilot valves provide reduced power consumption without any sacrifice of valve performance
  • Quiet, long-life solenoids can be quickly replaced without disturbing the hydraulic circuitry for easy maintenance
Pilot Valve Type N/A
Port Restrictor Plug Code None
Solenoid Double
Temperature Range [Min] -0.4 °F
Model No. DG5S4-02-2N-M-FTWL-B5-20
Electrical Options None
Mounting Subplate/Manifold Mount
Design No. 20
Manual Override Plain Override
Pressure Port Check Valve Pressure N/A
Coil Type 1/2 in NPT Thread Wiring Housing
Leakage Standard Performance
Housing Code W
Reducer Module N/A
Spool Spring Arrangement Code N
Spool Code 2
Coil Type Code F
Pressure Port Check Valve Code None
Temperature Range [Max] 150.8 °F
Crossover All Ports Blocked
Seal Material Buna-N
Assembly Code None
Pilot Pressure [Max] 3000 psi
Overrides Plain Override Solenoid Ends
Electrical Options Code None
Electrical Connection Wired Terminal Block
NFPA Size D05
Port Restrictor Plugs None
Coil Rating Code B
Spool Indicator Switch Code None
Actuator Type Solenoid
Solenoid Energization Code None
Fluid Cleanliness 19/17/14 micron
Center Position All Ports Blocked
Spool Control Modification Code None
Pilot Pressure Code None
Port T Pressure Rating 1450 psi
Response Type Code None
Body Material Gray Iron
Rated Flow [Max] 30 gal/min
Mechanical Options None
Pilot Drain Code None
Operation Solenoid Operated
Solenoid Indicator Lights Code L
Voltage & Frequency 110/120 VAC - 50/60 Hz
No. of Stages Two Stage
Pressure [Max] 3000 psi
Manual Override Option Code None
Mounting Screw Option Code None
Pilot Pressure [Min] 75 psi
Pilot Valve Tank Pressure Rating Code 5
EN Code None
Surge Suppressor/Damper None
AC/DC AC
Tank Port Rating 1450
Response Type Standard Response
Indicator Lights Yes
Function 3-Position Detented
Electrical Connector Code T
Pilot/Drain External Drain
Valve Type Standard-Duty
Actuation Identification Solenoid A, Solenoid B
Weight 13.0 LB