Vickers D03 Solenoid Valve

02-109979

Vickers D03 Solenoid Valve
Item #101958067
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Overrides No Overrides
Center Position All Ports Blocked
Housing Code None
Solenoid Energization Code None
Valve Type High-Performance
Manual Override Option Code None
Port T Code 7
Reducer Module No
Rated Flow [Max] 20 gal/min
Voltage & Frequency 24 VDC
Function 2-Position Spring Offset, Left Hand Build
Body Material Gray Iron
EN Code None
Spool Spring Arrangement Code A
Crossover All Ports Blocked
Temperature Range [Min] -4 °F
Solenoid Indicator Lights Code None
Compatible Fluids Petroleum Oil
Coil Type Code U
Mechanical Options None
Tank Port Rating 3046
Watt Rating 18 W
Mounting Subplate/Manifold Mount
Fluid Cleanliness 19/17/14 micron
Electrical Connection DIN 43650
AC/DC DC
Performance High Performance
No. of Stages Single Stage
Spool Shift Timing N/A
Design No. 60
Actuator Type Solenoid
Indicator Lights No
Seal Material Buna-N
Response Type Standard Response
Manual Override Plain Override
Electrical Connector Code None
Coil Type ISO 4400
Surge Suppressor/Damper None
Function Code 2
Surge Suppressor/Damper Code None
Electrical Options None
Operation Solenoid Operated
Pressure Port Check Valve Pressure N/A
Actuation Identification Solenoid A
Solenoid Single
Pilot/Drain None
Port T Pressure Rating 3000 psi
Temperature Range [Max] 158 °F
Model No. DG4V 3 2AL M U HL7 60
Cycle Rate [Max] N/A
Spool Indicator Switch Code None
Pressure [Max] 5000 psi
Leakage Standard Performance
NFPA Size D03
Coil Rating Code HL
Response Time 28 to 45 ms
Port Restrictor Plug Code None
Spool Code 2
Pilot Valve Type N/A
Solenoid Code HL
Port Restrictor Plugs None
Weight 5.0 LB