Replace valves easily. Simply remove three screws, lift off valve and replace. Even add or subtract valve manifold sections easily. Simply remove the end plate and add or remove manifold bases, as needed. Bases are connected with two bolts. Port sizes of 1/8" to 1/2" with ISO port identifications. Alpha subbase valves use the same solenoid coils and connectors as the Alpha body ported valves. Both end plates can be used for common supplies and exhaust in high flow applications. Solenoid coils sold separately..
features
Five-year warranty
Prelubricated for life
Wiring Options
None
Actuator Type
Solenoid
Return Type
Solenoid
Valve Body Style
Manifold Mounted
Voltage Rating
No Coil
Overrides
No Overrides
Temperature Range [Max]
180 °F
Coil Style
No Coil
Temperature Range [Min]
0 °F
Spool Seal Type
Urethane
Valve Duty
Standard Duty
Operation
Electric
Solenoid
Double
Stations
N/A
Port Size
None
Installed Options
None
Operating Pressure Range
20 psi to 150 psi
Series
Alpha Series
Cv Flow
1.3
Valve Type
4-Way, 2 Position
Spool Description
N/A
Weight
2.2 LB