Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Enclosure
XPFC
Drive End Bearing
6307
Voltage Rating
190, 460, 230, 380
Frame
213T
Brake Feature
No
Full Load Pf
80
Hz
60 Hz, 50 Hz
Open End Bearing
6206
Full Load rpm
1470 rpm, 1770 rpm
Washdown Duty
No
Rotation
R
Full Load Efficiency
91.7 %
Design
A
C Dimension
19.91 in
Phase
Three Phase
BALD Family Names
Premium Efficient, Explosion Proof
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
Mult. Sym.
L1
Motor Application
Explosion Proof
Product Line
RG
RPM
1800 rpm, 1500 rpm
Mounting Style
F-1
Service Factor
1
Motor Shaft Size
1 1/8 in
VoltCode
U
Poles
4
Frame Size
Shaft Input, Not a C-Face
Efficiency Group
Premium Efficient
Voltage
190/380/230/460
Motor Shaft Length
3 in
Mounting
Rigid Base
Type
X0740M
Full Load Amps
9
Useable at 208V
No
RefPicture
EM7064T
Weight
225.0 LB
EAN or UPC
781568220306
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back