Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Frame Size
Shaft Input, Not a C-Face
Efficiency Group
Premium Efficient
Washdown Duty
No
Full Load Pf
81
Rotation
R
Full Load Amps
18.7
Product Line
RG
Phase
Three Phase
Enclosure
TEFC
Design
B
Service Factor
1.15
C Dimension
27.76 in
C Face Kit
10-1305
Epact Nominal Full Load Efficiency
90.2 %
Voltage
230/460
Full Load Efficiency
92.4 %
Full Load rpm
1180 rpm
Useable at 208V
Yes
Drive End Bearing
6311
Brake Feature
No
Mounting Style
F-1
Type
1054M
Frame Material
Cast Iron
Open End Bearing
6309
Substitute Motor
EM4102T
Hz
60 Hz
RPM
1200 rpm
Motor Application
General Purpose
BALD Family Names
Premium Efficient, Nema Premium™
Mult. Sym.
L1
VoltCode
E1
Voltage Rating
460, 230
Poles
6
Frame
284T
Motor Shaft Size
1 7/8 in
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Mounting
Rigid Base
RefPicture
EMTECI
Motor Shaft Length
4 5/8 in
Weight
391.0 LB
EAN or UPC
781568103029
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back