Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Enclosure
TEFC
Full Load rpm
1160 rpm
VoltCode
E1
Drive End Bearing
6307
Full Load Efficiency
89.5 %
Design
B
Motor Application
General Purpose
Hz
60 Hz
Frame
213T
Product Line
RG
Type
3736M
Full Load Amps
5
RefPicture
EM3708T
Mounting
Rigid Base
Voltage Rating
460, 230
BALD Family Names
Premium Efficient, Nema Premium™
Brake Feature
No
Washdown Duty
No
Motor Shaft Size
1 3/8 in
Frame Size
Shaft Input, Not a C-Face
Epact Nominal Full Load Efficiency
87.5 %
RPM
1200 rpm
Phase
Three Phase
Useable at 208V
Yes
Frame Material
Steel
Voltage
230/460
Open End Bearing
6206
C Dimension
17.94 in
Efficiency Group
Premium Efficient
Rotation
R
C Face Kit
37-1304
Service Factor
1.15
Full Load Pf
64
Mult. Sym.
L1
Poles
6
Motor Shaft Length
3 3/8 in
Mounting Style
F-1
Weight
134.0 LB
EAN or UPC
781568139011
NEMA Premium
My Applied Catalog
We're here for you