Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Voltage
208-230/460
Full Load rpm
3450 rpm
RefPicture
EM3555T
Frame
145T
Useable at 208V
Yes
Frame Size
Shaft Input, Not a C-Face
Washdown Duty
No
Full Load Pf
85
Voltage Rating
460, 230, 208
Full Load Efficiency
86.5 %
BALD Family Names
Premium Efficient, Nema Premium™
Type
0532M
Efficiency Group
Premium Efficient
Mounting Style
F-1
Poles
2
Enclosure
TEFC
Mult. Sym.
L1
Hz
60 Hz
Motor Application
General Purpose, Premium Efficient
Design
B
Drive End Bearing
6205
Open End Bearing
6203
Brake Feature
No
Mounting
Rigid Base
Service Factor
1.15
RPM
3600 rpm
Frame Material
Cast Iron
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Phase
Three Phase
Rotation
R
Product Line
RG
VoltCode
E1
Full Load Amps
2.5
Weight
59.0 LB
EAN or UPC
781568677988