Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Full Load Efficiency
91.7 %
Washdown Duty
No
BALD Family Names
Premium Efficient, Nema Premium™
C Face Kit
37-1404
C Dimension
17.45 in
Motor Shaft Size
1 3/8 in
Poles
4
Full Load rpm
1760 rpm
Frame
215T
Enclosure Designation
OPSB - Open Slotted Band
Epact Nominal Full Load Efficiency
89.5 %
Drive End Bearing
6307
Open End Bearing
6206
Product Line
RG
Enclosure
OPSB
VoltCode
E1
Mounting
Rigid Base
Efficiency Group
Premium Efficient
Service Factor
1.15
Brake Feature
No
Type
3744M
Mult. Sym.
L1
Design
B
Frame Material
Steel
Voltage Rating
460, 230
RefPicture
EMDP
Full Load Amps
12.9
RPM
1800 rpm
Substitute Motor
EM3774T
Useable at 208V
Yes
Voltage
230/460
Frame Size
Shaft Input, Not a C-Face
Mounting Style
F-1
Rotation
R
Phase
Three Phase
Hz
60 Hz
Full Load Pf
80
Motor Shaft Length
3 3/8 in
Motor Application
General Purpose
Weight
128.0 LB
EAN or UPC
781568104767
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back