Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
BALD Family Names
Premium Efficient, Nema Premium™
Efficiency Group
Standard Efficient
Drive End Bearing
6309
Phase
Three Phase
Poles
6
Mounting
Rigid Base
Open End Bearing
6208
Epact Nominal Full Load Efficiency
90.2 %
Frame Size
Shaft Input, Not a C-Face
Motor Application
General Purpose
RefPicture
EMDP
Mounting Style
F-1
Frame Material
Steel
Full Load Efficiency
91.7 %
C Face Kit
39-1400
Voltage
230/460
Rotation
R
Full Load Amps
14.3
Type
3954M
Washdown Duty
No
Motor Shaft Length
4 in
Motor Shaft Size
1 5/8 in
C Dimension
23.19 in
Mult. Sym.
L1
Full Load rpm
1180 rpm
Enclosure Designation
OPSB - Open Slotted Band
Enclosure
OPSB
Frame
256T
Brake Feature
No
Design
B
RPM
1200 rpm
VoltCode
E1
Product Line
RG
Substitute Motor
M2511T
Voltage Rating
460, 230
Full Load Pf
71
Hz
60 Hz
Service Factor
1.15
Useable at 208V
Yes
Weight
245.0 LB
EAN or UPC
781568104804
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back