Baldor-Reliance® severe duty motors include features designed to protect against contamination, moisture, vibration and corrosion. These motors use Super-E® premium efficient electrical designs which are built to handle demanding duty cycles, provide high starting and peak torques, and operate over wide speed ranges. Severe Duty motors provide safe, long operating life, reliable performance, and reduced energy consumption in the toughest applications.
applications
Petro-chemical plants
Mines
Pulp and Paper plants
Chemical plants
features
Heavy duty cast iron construction
Premium efficient electrical designs
Enhanced ingress protection
Corrosion resistant epoxy finish
caution
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Efficiency Group
Standard Efficient
Full Load Efficiency
94.1 %
Washdown Duty
No
Frame
364TS
Motor Shaft Length
3 3/4 in
Motor Application
Severe Duty
Full Load Pf
90
Product Line
RG
Frame Size
Shaft Input, Not a C-Face
Service Factor
1.15
Model
841 XL
VoltCode
G
Enclosure
Totally Enclosed
HP [Min]
60
Rotation
R
RPM
3600 rpm
RefPicture
ECP03
Epact Nominal Full Load Efficiency
93 %
BALD Family Names
Premium Efficient, Nema Premium™, Severe Duty
Design
A
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Type
1458M
Frame Material
Cast Iron
Mult. Sym.
L1
Voltage Rating
460
Motor Shaft Size
1 7/8 in
Open End Bearing
6312
Useable at 208V
No
Poles
2
Mounting
Foot Mounted
Phase
Three Phase
Full Load Amps
67
Voltage
460
Mounting Style
F-1
Hz
60 Hz
Drive End Bearing
6313
Full Load rpm
3560 rpm
Brake Feature
No
C Dimension
30.13 in
Weight
905.0 LB