Baldor-Reliance® severe duty motors include features designed to protect against contamination, moisture, vibration and corrosion. These motors use Super-E® premium efficient electrical designs which are built to handle demanding duty cycles, provide high starting and peak torques, and operate over wide speed ranges. Severe Duty motors provide safe, long operating life, reliable performance, and reduced energy consumption in the toughest applications.
applications
Petro-chemical plants
Mines
Pulp and Paper plants
Chemical plants
features
Heavy duty cast iron construction
Premium efficient electrical designs
Enhanced ingress protection
Corrosion resistant epoxy finish
caution
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Rotation
R
Epact Nominal Full Load Efficiency
84 %
Full Load Pf
82
Full Load Efficiency
86.5 %
BALD Family Names
Premium Efficient, Nema Premium™, Severe Duty
Efficiency Group
Standard Efficient
Design
B
Type
0532M
Phase
Three Phase
C Face Kit
35-1300
Mounting Style
F-1
Frame Material
Cast Iron
C Dimension
12 3/4 in
Mounting
Foot Mounted
Voltage
460
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Brake Feature
No
Mult. Sym.
L1
RPM
1800 rpm
Service Factor
1.15
VoltCode
G
Full Load rpm
1725 rpm
Useable at 208V
No
Motor Shaft Size
7/8 in
Full Load Amps
2.7
Drive End Bearing
6205
Washdown Duty
No
Enclosure
Totally Enclosed
Frame
145T
Open End Bearing
6203
Motor Shaft Length
2 1/4 in
Product Line
RG
Frame Size
Shaft Input, Not a C-Face
RefPicture
ECP03
HP [Min]
2
Model
841 XL
Motor Application
Severe Duty
Hz
60 Hz
Voltage Rating
460
Poles
4
Weight
78.0 LB
EAN or UPC
781568210741