Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Rotation
R
VoltCode
F
Phase
Three Phase
Voltage
230/460
Mounting Style
F-1
Full Load rpm
1150 rpm
Product Line
RG
Useable at 208V
No
Mult. Sym.
L1
Design
B
Full Load Pf
63
Drive End Bearing
6205
Epact Nominal Full Load Efficiency
80 %
Enclosure
TEFC
Type
0528M
Efficiency Group
Premium Efficient
BALD Family Names
Premium Efficient, Nema Premium™
Poles
6
Full Load Efficiency
82.5 %
Motor Shaft Length
2 1/4 in
Motor Application
General Purpose
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Voltage Rating
460, 230
Service Factor
1.15
RefPicture
EMTECI
Frame
145T
Open End Bearing
6203
C Face Kit
35-1300
Full Load Amps
1.8
Washdown Duty
No
Frame Size
Shaft Input, Not a C-Face
Motor Shaft Size
7/8 in
Hz
60 Hz
RPM
1200 rpm
Mounting
Rigid Base
Frame Material
Cast Iron
Brake Feature
No
Weight
56.0 LB
EAN or UPC
781568204795
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back