Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Service Factor
1.15
Washdown Duty
No
Frame Size
Shaft Input, Not a C-Face
Full Load Pf
88
Mounting
Rigid Base
Full Load Efficiency
94.1 %
Motor Shaft Size
1 5/8 in
Type
4054M
Voltage
230/460
C Dimension
23.69 in
Frame Material
Steel
Useable at 208V
No
Mult. Sym.
L1
Poles
2
Efficiency Group
Premium Efficient
Rotation
R
Substitute Motor
M2538T
Brake Feature
No
RefPicture
EMDP
Frame
286TS
Hz
60 Hz
BALD Family Names
Premium Efficient, Nema Premium™
Phase
Three Phase
Full Load rpm
3540 rpm
C Face Kit
40-1400
Product Line
RG
VoltCode
F
Design
B
Full Load Amps
45
Motor Application
General Purpose
RPM
3600 rpm
Enclosure Designation
OPSB - Open Slotted Band
Enclosure
OPSB
Mounting Style
F-1
Drive End Bearing
6311
Motor Shaft Length
3 1/4 in
Voltage Rating
460, 230
Open End Bearing
6309
Epact Nominal Full Load Efficiency
91.7 %
Weight
378.0 LB
EAN or UPC
781568105108
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back