Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Enclosure Designation
OPSB - Open Slotted Band
Phase
Three Phase
Washdown Duty
No
Drive End Bearing
6311
Voltage Rating
460, 230
Full Load rpm
1770 rpm
Mounting
Rigid Base
Motor Shaft Size
1 7/8 in
Motor Shaft Length
4 5/8 in
C Dimension
25.06 in
BALD Family Names
Premium Efficient, Nema Premium™
Enclosure
OPSB
Full Load Pf
83
Mult. Sym.
L1
Frame
284T
Type
4046M
Hz
60 Hz
VoltCode
E1
Useable at 208V
Yes
Brake Feature
No
Motor Application
General Purpose
Full Load Amps
30
Service Factor
1.15
Open End Bearing
6309
RefPicture
EMDP
Efficiency Group
Premium Efficient
Epact Nominal Full Load Efficiency
91.7 %
Product Line
RG
Rotation
R
Frame Size
Shaft Input, Not a C-Face
RPM
1800 rpm
Frame Material
Steel
Poles
4
C Face Kit
40-1400
Substitute Motor
M2531T
Full Load Efficiency
94.1 %
Mounting Style
F-1
Design
B
Voltage
230/460
Weight
331.0 LB
EAN or UPC
781568104989
NEMA Premium