Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Phase
Three Phase
Mult. Sym.
L1
Useable at 208V
No
VoltCode
G
Brake Feature
No
Efficiency Group
Standard Efficient
Type
1266M
Voltage
460
C Face Kit
12-1105
Full Load Pf
87
Service Factor
1.15
Mounting
Foot Mounted
Voltage Rating
460
Design
B
Drive End Bearing
6312
Poles
4
Frame
326T
C Dimension
30 1/4 in
Full Load rpm
1775 rpm
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Full Load Amps
57
HP [Min]
50
Frame Material
Cast Iron
Epact Nominal Full Load Efficiency
93 %
Full Load Efficiency
94.5 %
Mounting Style
F-1
Model
XEX
Hz
60 Hz
Motor Shaft Size
2 1/8 in
Product Line
RG
Frame Size
326T
Enclosure
Totally Enclosed
Rotation
R
RPM
1800 rpm
Open End Bearing
6311
Motor Shaft Length
5 1/4 in
Washdown Duty
No
RefPicture
ECP03
Motor Application
Severe Duty
Weight
643.0 LB
EAN or UPC
781568107553
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back